This website uses cookies. For more information on our cookie policy click the link below.

  • SENSORS

F1 + Oxygen Sensor

F1 Oxygen Sensor

All technical information on this sensor is in the brochure below

please click the link for further information

Specifications


Application - Oxygen enrichment/depletion measurement
Nominal Range - 0~25% Oxygen
Max Overload - 30% Oxygen
Sensing Principle - Self powered diffusion limited, metal-air battery (electrochemical) - 4 series
Replacement Sensor Insert - 3 pin device - part No 010-410
Certification
ATEX
No. SIRA 03 ATEX 1176X
IECEx
No. SIR 06.0016X
II 2 GD
Exd II C T6 Gb -20˚C Ta +35˚C
Extb III C T85˚C Db
Exd II C T5 Gb -20˚C Ta +50˚C
Extb III C T100˚C Db
Exd II C T4 Gb -20˚C Ta +85˚C
Extb III C T135˚C Db
Exd II C T3 Gb -20˚C Ta +120˚C
Extb III C T200˚C Db
Housing Material - Stainless Steel 316-S16
Dimensions - Length 32mm. Diameter 33.3mm
Cable Exit Mounting Thread (A)
20mm 1.5 pitch standard
25mm 1.5 pitch option
3/4 NPT – 14 option
Accessory Mounting Thread (B) - 33.3mm 1.25 pitch
Lock Screen - 3mm – 1mm key
Housing Components - Body Ref. 001-002 / End Cap Ref. 001-003
Ingress Protection - IP63 + universal fitting IP64 + water shield IP65
UK Design Patent - No. 2025396


PERFORMANCE DATA
Expected Operating Life -
Two years in air
Output Signal - 0.225± 0.025 mA in aIr
Temperature Range -20°C to +50°C – cell see certification for Ex use
Pressure Range - Atmospheric ± 10%
T90 Response Time - 15 seconds
Temperature Range -20°C to +50°C
Temperature Coefficient - 0.2% signal/°C
Pressure Range - Atmospheric ± 10%
Pressure Coefficient <0.02% signal/mBar (typ.0.01%)
Operating Humidity - 0 to 99% RH non-condensing
Long Term Output Drift < 5% signal loss/year
Recommended Load Resistor - 100Ω
Position Sensitivity - None
Storage Life - Six months in shipping container
Recommended Storage Temperature - 0~20°C